home *** CD-ROM | disk | FTP | other *** search
/ Aminet 32 / Aminet 32 (1999)(Schatztruhe)[!][Aug 1999].iso / Aminet / hard / drivr / ScanTek4_5.lha / ScanTek / ReadMe < prev    next >
Text File  |  1999-05-04  |  14KB  |  419 lines

  1.  
  2.                         ScanTek 4.5
  3.  
  4.                     A scanner driver for
  5.                Microtek, Highscreen and Mustek
  6.                       Flatbed Scanner
  7.  
  8.  
  9.         © Copyright 1995/96/97/98/99 Waldemar Zöhner
  10.     email: scantek@gmx.de, wzoehner@gmx.de oder wzoehner@odn.de
  11.        http://www.users.odn.de/~odn05111/scantek.html
  12.  
  13.                   Get It, Feel It, Love It
  14.  
  15.  
  16.  Overview
  17. ----------
  18.  
  19.  The ScanTek scanner driver has the following features:
  20.  
  21.  1. Support of the following SCSI Microtek scanner models:
  22.         MICROTEK IISP, MICROTEK II, HIGHSCREEN Flatbed Color IIs,
  23.         ScanMaker E3, ScanMaker 35t, ScanMaker E6,
  24.         Highscreen PerfectScan, older Highscreen HighScan
  25.  
  26.         Microtek ScanMaker 636, 336 and x6
  27.  
  28.         Microtek E3PLUS, V300, 330, 630 and new Highscreen HighScan
  29.  
  30.            This new scanner model can be used in black&white, grey scale
  31.            and color scanning.
  32.            The download of color lookup tables (gamma curves) is now
  33.            supported.
  34.            Color scan images can contain a shifted segment, if the image
  35.            data is written to a harddisk on the same SCSI host adapter.
  36.            The image data should be written to a harddisk on another SCSI
  37.            host adapter or to a IDE harddisk.
  38.  
  39.  
  40.     Support of the following SCSI Mustek Paragon scanner models:
  41.         Three Pass Scanners:
  42.         Paragon 6000CX, 8000CX (not tested), 12000CX all should work
  43.  
  44.         One or Single Pass Scanners:
  45.         Paragon 6000SP, 8000SP, 12000SP (now supported) all should work
  46.         Paragon 6000CZ, 8000CZ (not tested)
  47.  
  48.         Paragon 600IISP, 800IISP
  49.  
  50.  
  51.     The following scanner models are in the development phase:
  52.         none
  53.  
  54.  
  55.     The following scanner models are recognized but not fully supported: 
  56.         Mustek ScanExpress 12000SP
  57.         Mustek Paragon 1200IIISP (caution: III -> version 3)
  58.            Color scanning is only successfull at resolutions of 150, 300,
  59.            600 and 1200 dpi.
  60.            Grey scale scanning is possible.
  61.            If the image to be scanned exceeds the scan buffer size than
  62.            the image is corrupt. This effect is independent from the
  63.            scan mode.
  64.            The scanning quality is also (!) dependent from the used
  65.            SCSI host adapter.
  66.            The ScanExpress or Paragon 12000IIISP scanner models are
  67.            not recommended for ScanTek.
  68.            At least until sometimes in the future the corresponding
  69.            Mustek SCSI programming documentation for these new models
  70.            is available. I think this might be a Millenium projekt.
  71.  
  72.  
  73.     The following scanner models are not supported by now: 
  74.         All remaining Mustek ScanExpress and Paragon IIISP models.
  75.  
  76.  
  77.     The following scanner models are not supported:
  78.         Canon, Epson, HP, Umax and any parallelport scanner.
  79.  
  80.  
  81.     Attention: In recent times Mustek has changed the scanner firmware.
  82.                I urge you to test Mustek scanners with your Amiga
  83.                configuration before buying it.
  84.  
  85.                Mustek scanners have a critical SCSI interface. It
  86.                was reported to me that these scanners may not work
  87.                with the A2091 and A3000(T) internal SCSI interface.
  88.                It is possible that these scanners do not work with
  89.                other SCSI host adapters, either.
  90.                But the Mustek 6000CX and Paragon MFS-12000SP work in
  91.                combination with an Oktagon SCSI host adapter.
  92.                Be sure to disable reselection for Mustek scanners
  93.                on your SCSI host adapter. Otherwise your system may
  94.                not boot.
  95.  
  96.  2. Support of black/white, built-in halftone (dither), one-pass-color-scan,
  97.     three pass color scan, grey, red, green and blue scan.
  98.  
  99.  3. Individual setting of resolution, scanning frame, contrast, shadow,
  100.     midtone, highlight, exposure time and scanning speed for download to the
  101.     scanner.
  102.  
  103.  4. Download of a color look up table (gamma correction table ) to the scanner
  104.     supported.
  105.  
  106.  5. Scanning to IFF File of 1, 8 or 24 bit color depth. The maximum size of
  107.     the scanned image is independent from the RAM size. After the scanning
  108.     process it is possible to start an external program.
  109.  
  110.  6. GUI for preview and configuration of the driver. You need Kickstart 2.04
  111.     but Kickstart 3.0 is recommended.
  112.  
  113.  7. Sizeable preview window in black/white or grey scale. Color preview
  114.     on Cybergraphix screens (15, 16 or 24 bit necessary).
  115.     There are much more skilled programs to view and manipulate the scanned
  116.     images in color. (A tool like ADPRO, IMAGE FX or so is needed, if you
  117.     want to do sophisticated postproduction)
  118.  
  119.  8. ARexx support
  120.  
  121.  9. Screenmode requester to define custom screen for working. The actual public
  122.     screen is supported as well
  123.  
  124.  10. Configurable SCSI device and SCSI ID. The driver supports only SCSI
  125.      connectable scanners.
  126.  
  127.  11. The driver is tested with the following SCSI drivers: oktagon.device and
  128.      gvpscsi.device V4.5.
  129.  
  130.  12. ScanTek is written using SAS C 6.58.
  131.  
  132.  13. ScanTek is SHAREWARE.
  133.  
  134.  14. The non registered version of ScanTek is a full working version, but all
  135.      scanned images have black lines to motivate you to register.
  136.      Additionally the maximum size of the preview is restricted.
  137.  
  138.  
  139.  History
  140. ---------
  141.  
  142.  V4.5  5 May 1999
  143.  
  144.    - Untested support for new flavour of Microtek ScanMaker X6
  145.  
  146.  
  147.  V4.4  3 February 1999
  148.  
  149.    - Better Surfsquirrel SCSI support. New Microtek scanner should work
  150.      now after activating the Surfsquirrel SCSI Workaround.
  151.      Other SCSI Hostdapter may work as well after activating this
  152.      Workaround.
  153.  
  154.  
  155.  V4.3  6 December 1998
  156.  
  157.    - Support of the transparency adapter and control of the scanning and
  158.      transparency medium lamp for Microtek 63x, 33x and compatible
  159.      Highscreen HighScan scanner models
  160.  
  161.  
  162.  V4.2  9 September 1998
  163.  
  164.    - Locale catalogs now updated correctly
  165.  
  166.    - No color failures if the LookUp tables are deactivted for
  167.      Microtek 630, 330 and new Highscan II models
  168.  
  169.  
  170.  V4.1 29 August 1998
  171.  
  172.    - Full support for Microtek 630, 330 and new Highscan II models
  173.      - Color LookUp tables now supported
  174.      - Faster preview for new generation of ScanMaker scanners
  175.  
  176.    - ScanTek support homepage has been moved to
  177.        http://www.users.odn.de/~odn05111/scantek.html
  178.  
  179.    - Enhanced screen mode handling on program startup
  180.  
  181.  
  182.  V4.0 19 June 1998
  183.  
  184.    - Localization of ScanTek. Supported locales: english, deutsch, dansk
  185.  
  186.    - New email address: scantek@gmx.de, wzoehner@gmx.de
  187.  
  188.  
  189.  V3.11 24 May 1998
  190.  
  191.    - Support of the new Highscreen HighScan II (Microtek) and
  192.      the new version of the Microtek E3Plus
  193.  
  194.  
  195.  V3.10 17 April 1998
  196.  
  197.    - First attempt to support the new Microtek 330 scanner model.
  198.      The scanning speed depends in a large degree on the SCSI host adapter.
  199.      This scanner model may lead to hang ups of the SCSI bus (computer
  200.      system) on critical SCSI devices.
  201.  
  202.  
  203.  V3.9  15 March 1998
  204.  
  205.    - Better support for Mustek ScanExpress 12000SP and the identical
  206.      international Mustek Paragon 1200 III SP.
  207.      This scanner model is not recommended for ScanTek.
  208.        Preview works now also on small preview windows.
  209.        Color scanning is only successful at resolutions of 150, 300,
  210.        600 and 1200 dpi.
  211.        Only small scanning images are successful. The automatic segment
  212.        scanning is not possible on this scanner model.
  213.  
  214.    - The new Microtek model ScanMaker E3PLUS is in the testing phase.
  215.      (see Overview for details)
  216.    
  217.    - Microtek V300, Microtek 330, Microtek 630
  218.        These scanner models are due to the documentation related to           
  219.        the Microtek E3PLUS. They should work in an equivalent way.
  220.  
  221.  
  222.  V3.8  23 February 1997
  223.  
  224.    - Bugfix of Mustek color scan process (Scrambled image data in
  225.      segment scanning)
  226.  
  227.    - Support of Transparency Adapter (Slide Kit Unit) enhanced
  228.  
  229.    - First attempt to support the new european Mustek
  230.      ScanExpress 12000SP and international Mustek Paragon 1200 III SP.
  231.      These scanners are assumed to be identical.
  232.      Due to missing Mustek programming documentation for the new firmware
  233.      there is only a limited support of these scanner models:
  234.        ... Gray scale scanning is supported.
  235.        ... Color scanning is incorrect and is therefore unusable
  236.      These scanner models are not recommended for the use with ScanTek.
  237.      If there will be a Mustek programming documentation some time in the
  238.      future than a second attempt for the support will be made.
  239.  
  240.  
  241.  V3.7  30 December 1997
  242.  
  243.    - Detection of Mustek scanners enhanced
  244.      Erkennung von Mustek Scannern weiterentwickelt
  245.  
  246.    - German Documentation
  247.      Deutsche Anleitung
  248.  
  249.  
  250.  V3.6  21 December 1997
  251.  
  252.    - The Mustek MFS-12000SP is now supported
  253.    - Rework of ASL requester handling
  254.    - PROGDIR: usage reduced
  255.  
  256.  
  257.  V3.5  4 December 1997
  258.  
  259.    - Rework of window activation procedures
  260.    - Rework of font sentivity
  261.    - PROGDIR: usage reduced
  262.    - Support of multiple SCSI host adapters in one system
  263.  
  264.  
  265.  V3.4  21 October 1997
  266.  
  267.    - Support of Transparency Adapter (Slide Kit Unit)
  268.    - Prevent system lockup during startup on Dataflyer SCSI+ host
  269.      adapter
  270.  
  271.  
  272.  V3.3   1 August 1997
  273.  
  274.    - Detection of ScanMaker35t+ introduced 
  275.    - Faster preview scanning process on some scanner models
  276.    - "Accurate Coordinates" support for ScanMaker E6 and compatible
  277.  
  278.  
  279.  V3.2   8 June 1997
  280.  
  281.    - Workaround for surfsquirrel.device to avoid SCSI bus hangup
  282.    - AREXX scripts: Load scanned pictures into 
  283.                     ImageFX:   ST2ImageFX.strx
  284.                     ArtEffect: ST2ArtEffect.strx
  285.  
  286.  
  287.  V3.1  19 May 1997
  288.  
  289.    - Recognition of Highscreen PerfectScan (600dpi) introduced
  290.    - Recognition of Highscreen RealScan (300dpi) introduced
  291.    - Activation of newly opened windows works now correct
  292.  
  293.  
  294.  V3.0   16 Apr. 1997
  295.  
  296.    - AREXX support
  297.    - XBMI-chunk introduced to store DPI (dots per inch) information in
  298.      IFF File
  299.    - Handling of Microtek ScanMaker E6 enhanced
  300.    - Bugfixes: "Exposure Time" and "Contrast" parameters for Microtek
  301.                and some Mustek scanner models are now correct.
  302.                This bug could lead to images that where to light.
  303.                Grey preview of color image now work with all specified
  304.                settings.
  305.  
  306.  
  307.  V2.10 26 Mar. 1997
  308.  
  309.    - Full size preview on 400 dpi Mustek scanners adjustable
  310.  
  311.  
  312.  V2.9   9 Feb. 1997
  313.  
  314.    - Look Up Table Window redesigned to ensure font sensitivity
  315.  
  316.  
  317.  V2.8  11 Jan. 1997
  318.  
  319.    - New icons for ScanTek
  320.    - Recognition and handling of new Mustek scanners enhanced
  321.    - Minior bug fixes
  322.    - Introduction of the ScanTek Support WebSite
  323.  
  324.  
  325.  V2.7  6 Dec. 1996
  326.  
  327.    - Recognition and handling of new Mustek scanners enhanced
  328.    - Recognition of Microtek ScanMaker E6 adapted
  329.  
  330.  
  331.  V2.6  30 Oct. 1996
  332.  
  333.    - Full support of Mustek one pass scanners
  334.    - Recognition of Mustek scanners enhanced
  335.  
  336.  
  337.  V2.5  5 Oct. 1996
  338.  
  339.    - Workaround to handle strange color mode behaviour of Mustek
  340.      one pass scanners
  341.    - Reverse scanning in black and white mode introduced
  342.  
  343.  
  344.  V2.4 10 Sept. 1996
  345.  
  346.    - Support of Mustek SCSI one pass color scanners in color mode and
  347.      parameter ranges.
  348.    - ScanTek can now open its GUI windows on the actual public screen.
  349.  
  350.  
  351.  V2.3  6 Sept. 1996
  352.  
  353.    - Color Preview on Cybergraphix screens in true color mode
  354.      (15, 16 or 24 bit) for onepass flatbed scanners
  355.    - Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
  356.      (15, 16 or 24 bit) for threepass and onepass flatbed scanners
  357.    - Change and recall of predefined resolution values
  358.  
  359.  
  360.  V2.2 26 July 1996
  361.  
  362.    - Enhanced support for Mustek scanners
  363.      "Exposure Time" and "Contrast" parameters are now correct
  364.    - Gamma value "All" now works on threepass scanner
  365.    - Alternative Black/White scanning mode
  366.  
  367.  
  368.  V2.1  5 July 1996
  369.  
  370.    - Preview now fully supported for Mustek 6000CX
  371.    - Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame
  372.  
  373.  
  374.  V2.0  30 Apr. 1996
  375.  
  376.    - Preview in color mode with proper options values
  377.    - Use of expanded Contrast and Exposure Time selections on certain scanners
  378.    - X and Y Aspect Ratio in color images is correct now
  379.    - ScanMaker E3 does not support undocumentated red, gree and blue scanning
  380.    - Lookup Table command supported (Gamma Correction on certain scanner
  381.      possible)
  382.    - Scanning Frame Setting is now more intuitive
  383.    - Reverse image scanning supported (only on certain scanners possible)
  384.    - Accurate scanning supported. Scanning frame is now more precise.
  385.  
  386.  
  387.  V1.3  25 Feb. 1996
  388.  
  389.    - Detection of new ScanMaker E3 Flatbed scanner implemented
  390.    - Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
  391.      (due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
  392.    - No start of the external program, if the scanning process is aborted
  393.    - Higher dpi rates for ScanMaker 35t (slide scanner) possible
  394.      Preview image should look better now.
  395.    - "Main Control" window and gadgets modified
  396.    - Debug filename "ScanTek.log" can be overriden through CLI or Tooltype
  397.  
  398.  
  399.  V1.2   3 Jan. 1996
  400.  
  401.    - Debug output data revised and enhanced
  402.    - Max Frame Setting setting introduced
  403.    - Start of external program possible
  404.    - Window positions are remembered and saved
  405.    - Configuration file enhanced
  406.  
  407.  
  408.  V1.1  17 Dec. 1995
  409.  
  410.    - detection of Microtek scanner via SCSI inquiry enhanced
  411.    - stepping of resolution slider adapted to expanded base resolution
  412.    - calculation of scanning frame size data modified
  413.  
  414.  
  415.  V1.0  30 Nov. 1995
  416.  
  417.    - first public release
  418.  